Skip to main content
. 2013 Oct 31;13(11):14813–14838. doi: 10.3390/s131114813

Table 3.

List of the selected reference on chemical sensor based on titania nanotubes.

Reference Preparation Contacts Gas Carrier Measurement Gas
[89] Ti foil anodization Pt N2 Dynamic flow H2, CO, NH3
[93] Ti foil anodization Pt N2 Dynamic flow O2
[12] Ti foil anodization Pt N2 Dynamic flow H2
[92] Ti foil anodization Au + Ag N2 Dynamic flow H2
[10] Ti foil anodization Ag N2 Dynamic flow SO2
[94] Ti foil anodization Pt Ar Dynamic flow NO2, CO
[96] Ti foil anodization Stainless steel Air Static Ethanol, NH3
[73] Ti foil anodization Pt Ar Static H2
[72] Ti foil anodization Ag+Au Air Static ethanol
[87] Ti film on glass Au Air Static Volatile organic compounds
[95] ALD Pt Air Dynamic flow H2, CO, ethanol, NH3
[98] Ti35Nb foil anodization Pt + Ag + Cu Air, N2 Dynamic flow H2
[39] Ti film on alumina anodization Pt Air Dynamic flow CO, ethanol
[47] Ti/Nb film on alumina anodization Pt Air Dynamic flow CO, NO2, H2, ethanol, acetone