Calculation of UV reflection.

Note: Calculation of UV reflection according to the formula used in the International Organization for Standardization standard for UV transmission. Spectral ellipsometry and variable angle spectrophotometry in both the UV and visible range are used to characterize every material, be it substrate or thin layer. Spectral reflection measurements on concave (back side) were performed on antireflective lenses using a spectrometer (MCS501, Carl Zeiss Meditec AG, D-Jena, Germany) and a specific lens holder designed by Essilor International SA (F-Charenton-le-Pont, France) that allows measurements at different angles in the 30°–45° range, corresponding to real-life back side solar exposure for a wearer in the 135°–150° range.