Skip to main content
. Author manuscript; available in PMC: 2015 Jan 1.
Published in final edited form as: Ear Hear. 2014 Jan-Feb;35(1):10.1097/AUD.0b013e3182a3648b. doi: 10.1097/AUD.0b013e3182a3648b

Table 5.

Domain and Subscale scores for UHL, CICI, and CIHA participants.

UHL CICI CIHA
Speech Domain mean 5.5 6.4 6.0
SD 1.6 1.7 1.0
range 1.9 – 8.1 3.3 – 9.6 4.5 – 7.9

Spatial Domain mean 3.6 6.0 4.6
SD 1.9 2.2 1.7
range 1.0 – 7.3 1.5 – 9.5 2.4 – 8.4

Qualities Domain mean 6.5 7.3 6.5
SD 1.6 1.5 1.2
range 3.6 – 9.2 4.3 – 9.7 4.3 – 8.3

Speech in Quiet SiQ mean 7.9 8.8 8.4
SD 1.6 1.1 0.8
range 3.0 – 10.0 6.0 – 10.0 7.0 – 10.0

Speech in Noise SiN mean 5.0 6.2 6.0
SD 1.9 1.9 1.1
range 1.5 – 8.0 3.3 – 9.3 4.5 – 7.9

Speech in Speech Contexts SiSCont mean 5.6 6.4 5.9
SD 2.1 1.9 1.1
range 1.0 – 9.0 3.3 – 9.8 3.8 – 8.0

Multiple Speech Stream Processing and Switching MultStream mean 3.9 4.8 4.7
SD 1.7 2.4 1.7
range 1.0 – 7.3 0.7 – 9.7 2.0 – 7.2

Localization Loc mean 3.1 6.0 4.9
SD 2.5 2.9 1.6
range 0.0 – 7.8 0.5 – 9.5 2.5 – 8.2

Distance and Movement DisMov mean 3.9 5.8 4.4
SD 2.0 2.3 1.9
range 1.0 –7.3 1.6 – 9.7 1.8 – 8.8

Segregation of Sounds SegSnds mean 6.4 7.6 6.3
SD 2.2 1.8 1.8
range 0.7 – 10.0 4.5 – 10.0 3.3 – 10.0

Identification of Sound and Objects IdSnd mean 7.9 7.4 6.8
SD 1.7 1.9 1.2
range 3.2 – 10.0 3.4 – 9.7 4.4 – 8.6

Sound Quality and Naturalness Qlty mean 7.5 7.6 6.7
SD 1.9 1.9 1.6
range 2.9 – 10.0 4.0 – 9.8 3.0 – 9.2

Listening Effort Eff mean 4.1 6.6 5.7
SD 2.0 2.1 1.5
range 0.3 – 7.7 3.3 – 10.0 3.3 – 8.3

Note: UHL = unilateral hearing loss; CICI = bilateral cochlear implants; CIHA = cochlear implant and hearing aid