Skip to main content
. 2004 May;72(5):2659–2670. doi: 10.1128/IAI.72.5.2659-2670.2004

TABLE 2.

Detection of pneumococci in lung homogenates of mice immunized with BVH-3M, BVH-11M, or the chimeric CH-3C-11B recombinant protein

Immunogen CFU/100 μl of lung homogenatesa
Day 2 postinfection Day 3 postinfection
BVH-3M 191 (10, 15, 150, 150, 630) 24 (< 5, < 5, < 5, < 5, 100)
BVH-11M 148 (10, 25, 70, 135, 500) 4 (< 5, < 5, < 5, < 5, < 5)
CH-3C-11B 56 (<5, <5, <5, <5, 260) 159 (< 5, < 5, 20, 75, 690)
Quil A alone 4.3 × 105 ([2.8, 3.2, 4.6, 7.0, 8.0] × 105) 2.4 × 106 ([1.9, 2.2, 3.2] × 106)b
a

Arithmetic mean of CFU values. CFU values for individual mice are indicated in parentheses. Values of 4 and 6.6 × 106 CFU/100 μl were assigned to samples without any colonies and to dead animals, respectively, to calculate arithmetic means.

b

In two mice from the Quil A group, death occurred between day 2 and day 3 postinfection.