Skip to main content
. 2013 Dec 11;7(2):456–460. doi: 10.3892/etm.2013.1445

Table II.

Diagnosis of sentinel lymph node metastases.

A. Postoperative diagnosis

Postoperative diagnosis SLN or non-SLN-positive SLN and non-SLN-negative Total
SLN-positive 54 0 54
SLN-negative 2 47 49
Total 56 47 103

B. Intraoperative diagnosis

Intraoperative diagnosis SLN-positive SLN-negative Total

SLN-positive 54 0 54
SLN-negative 8 300 308
Total 62 300 362

Postoperative diagnosis: The sensitivity for sentinel lymph node (SLN) metastasis was 96.4%, the specificity was 100% and the false-negative rate was 3.6%. Intraoperative diagnosis: A diagnostic accuracy of 97.8%, a sensitivity of 87.1% and specificity of 100% were achieved with hematoxylin and eosin (H&E) staining in the frozen sections; the false-negative rate was 12.9%.