Table II.
A. Postoperative diagnosis | |||
---|---|---|---|
| |||
Postoperative diagnosis | SLN or non-SLN-positive | SLN and non-SLN-negative | Total |
SLN-positive | 54 | 0 | 54 |
SLN-negative | 2 | 47 | 49 |
Total | 56 | 47 | 103 |
| |||
B. Intraoperative diagnosis | |||
| |||
Intraoperative diagnosis | SLN-positive | SLN-negative | Total |
| |||
SLN-positive | 54 | 0 | 54 |
SLN-negative | 8 | 300 | 308 |
Total | 62 | 300 | 362 |
Postoperative diagnosis: The sensitivity for sentinel lymph node (SLN) metastasis was 96.4%, the specificity was 100% and the false-negative rate was 3.6%. Intraoperative diagnosis: A diagnostic accuracy of 97.8%, a sensitivity of 87.1% and specificity of 100% were achieved with hematoxylin and eosin (H&E) staining in the frozen sections; the false-negative rate was 12.9%.