Comparison of Adverse Events in Previous Large Series of PDA Closure

Report Timeframe Subjects Weight Device Type Adverse Event Rate Major Adverse Event Rate
Tometzki et al1 1994–1995 71 16.4 Cook coil 4 (5.6%) 1 (1.4%)
PDA coil registry10 1993–1995 523 Gianturco coil 151 (28.9%) 116 (22.2%)
Faella and Hijazi2 1996–1999 316 10.7 ADO 15 (4.7%) 1 (0.3%)
Pass et al3 1999–2002 439 11 ADO 41 (7.1%) 10 (2.3%)
Jang et al4 1999–2005 117 30 ADO, Nit‐Occlud, Cook 6 (5.1%) 4 (3.4%)
Dimas et al8 1995–2005 62 4.6 Gianturco coil, Gianturca‐Grifka VOD, ADO 8 (13%) 4 (6.5%)
Wang et al13 2002–2008 46 6.3 ADO 13 (28.3%) 3 (6.5%)
Ghasemi et al12 1994–2007 546 19.9 Gianturco coil, Flipper coil, ADO, Nit‐Occlud 47 (8.6%) 21 (3.8%)
Brunetti et al11 2005–2008 359 18.7 Gianturco coils, Flipper coils, ADO, other devices 16 (4.5%) 8 (2.2%)

ADO indicates Amplatzer Ductal Occluder; PDA, patent ductus arteriosus; VOD, vascular occlusion device.