Skip to main content
. Author manuscript; available in PMC: 2014 Jan 13.
Published in final edited form as: Med Image Comput Comput Assist Interv. 2010;13(0 1):502–509. doi: 10.1007/978-3-642-15705-9_61

Table 2.

Sample means and standard deviations of quality indices (n=28) for segmentations obtained on frames from ventricular ejection

Chan-Vese Proposed Algorithm
Performance Measures Dice HD MAD Dice HD MAD
Average 0.653 9.823 1.812 0.723 9.426 1.872
STD 0.036 4.732 0.497 0.056 2.936 0.363