Four-point monotonic test data, incorporating the area moment of inertia

Manufacturer Yield load (N) Area moment of inertia (mm4) Normalized bending strength (N/mm3) Normalized bending structural stiffness (N/mm2)
HIC(1) 606.5 ± 55.5 29.9 ± 1.0 325.6 ± 36.7 185100 ± 6273
HIC(2) 632.5 ± 46.0 28.2 ± 0.5 359.4 ± 23.2 182200 ± 6835
LMIC(A1) 530.2 ± 59.7 32.7 ± 0.4 259.5 ± 29.8 188300 ± 8039
LMIC(A2) 817.5 ± 19.6 34.5 ± 0.4 379.3 ± 9.6 203600 ± 2295
LMIC(A3) 644.5 ± 252.1 41.1 ± 5.2 245.7 ± 63.9 183800 ± 8643
LMIC(B1) 322.5 ± 37.2 25.0 ± 1.5 207.1 ± 24.7 190400 ± 13190
LMIC(B2) 415.8 ± 30.6 28.7 ± 0.7 231.6 ± 15.7 192300 ± 7779
LMIC(B3) 342.8 ± 29.9 28.3 ± 2.9 197.3 ± 37.6 204400 ± 24550