Skip to main content
. 2013 Dec 1;29(1):1–6. doi: 10.1093/arclin/act088

Table 2.

Sensitivity and specificity of clock drawing in predicting unsafe driving (n = 122)

Scoring system Sensitivity Specificity
7-point (AUC = 0.61, 95% CI = 0.51–0.71)
 0 1.00 0.00
 1.5 0.99 0.08
 2.5 0.91 0.15
 3.5 0.78 0.30
 4.5 0.69 0.41
 5.5 0.43 0.72
 6.5 0.18 0.98
8-point (AUC = 0.60, 95% CI = 0.50–0.71)
 0 1.00 0.00
 1.5 1.00 0.06
 2.5 1.00 0.15
 3.5 0.95 0.17
 4.5 0.89 0.19
 5.5 0.86 0.29
 6.5 0.72 0.44
 7.5 0.50 0.62
10-point (AUC = 0.58, 95% CI = 0.48–0.69)
 0 1.00 0.00
 1.5 1.00 0.02
 2.5 1.00 0.03
 3.5 1.00 0.04
 4.5 0.97 0.15
 5.5 0.90 0.17
 6.5 0.82 0.25
 7.5 0.77 0.31
 8.5 0.62 0.54
 9.5 0.34 0.75
Conceptualization (AUC = 0.53, 95% CI = 0.43–0.64)
 Yes/No 0.71 0.35

Notes: AUC = area under the curve; CI = confidence interval.