Table 3.

Parameters that were measured to evaluate their impact on the occurrence of high serum indices in clear serum samples; methods, measuring ranges, instruments and reagent manufacturers.

Analyte Instrument Method Measuring range Manufacturer
IgG Siemens BN II nephelometer Nephelometric method 1.4–64.0 g/L1 (1/400 dilution) Siemens HealthCare Diagnostics Products GmbH, Marburg, Germany
IgA Siemens BN II nephelometer Siemens BN II nephelometer Nephelometric method Siemens BN II nephelometer Nephelometric method 0.23–8.00 g/L2 (1/20 dilution) Siemens HealthCare Diagnostics Products GmbH, Marburg, Germany
IgM IgM Siemens BN II nephelometer IgM Siemens BN II nephelometer Nephelometric method 0.18–6.40 g/L2 (1/20 dilution) Siemens HealthCare Diagnostics Products GmbH, Marburg, Germany
Kappa light chains Kappa light chains Siemens BN II nephelometer Nephelometric method 0.28–9.10 g/L1 (1/20 dilution) Siemens HealthCare Diagnostics Products GmbH, Marburg, Germany
Lambda light chains Siemens BN II nephelometer Nephelometric method 0.16–5.00 g/L1 (1/20 dilution) Siemens HealthCare Diagnostics Products GmbH, Marburg, Germany
Monoclonal immunoglobulin Monoclonal immunoglobulin Interlab Microtech 648 PC Monoclonal immunoglobulin Interlab Microtech 648 PC Serum protein electrophoresis / 3 Interlab Scientific Instruments, Roma, Italy
Monoclonal immunoglobulin Sebia Hydrasis Immuno-electrophoresis / 4 Sebia, Lisses, Cedex, France
Total cholesterol Total cholesterol Siemens Dimension RXL Max, Vista Cholesterol esterase 1.30–15.50 mmol/L2 Siemens HealthCare Diagnostics, Newark, DE, USA
Triglycerides Siemens Dimension RXL Max, Vista GPO-PAP Enzymatic 0.02–11.30 mmol/L2 Siemens HealthCare Diagnostics, Newark, DE, USA
HDL cholesterol Siemens Dimension RXL Max, Vista Homogenous direct (enzymatic colorimetric) method 0.05–3.89 mmol/L2 Siemens HealthCare Diagnostics, Newark, DE, USA
LDL cholesterol Siemens Dimension RXL Max, Vista Direct (enzymatic colorimetric) method 0.00–7.80 mmol/L2 Siemens HealthCare Diagnostics, Newark, DE, USA
Total protein (TP) Siemens Dimension RXL Max, Vista Photometric colour test (biuret) 0–120 g/L2 Siemens HealthCare Diagnostics, Newark, DE, USA
Lp(a) Siemens BN ProSpec nephelometer Nephelometric method 0.10–1.60 g/L1 Siemens HealthCare Diagnostics Products GmbH, Marburg, Germany
ApoA1 Siemens BN II nephelometer Nephelometric method 0.19–6.00 g/L1 Siemens HealthCare Diagnostics Products GmbH, Marburg, Germany
ApoB Siemens BN II nephelometer Nephelometric method 0.25–4.00 g/L2 Siemens HealthCare Diagnostics Products GmbH, Marburg, Germany
Rheumatoid factor (RF) Siemens BN ProSpec nephelometer Nephelometric method 10–600 IU/mL2 Siemens HealthCare Diagnostics Products GmbH, Marburg,
Cryoglobulins PU 8675 VIS Spectrophotometer Lowry method 0–400 mg/L Germany Philips, Cambridge, United Kingdom
Serum index Olympus AU640 LIH / Olympus Diagnostica GmbH, Lismeehan, Ireland5
Serum index Hitachi 911 LIH / Roche Diagnostics GmbH, Mannheim, Germany
Serum index Siemens Dimension RXL Max, Vista HIL / Siemens HealthCare Diagnostics, Newark, DE, USA
1

A change of lower and upper range value is possible with dilution of the sample.

2

A change of upper range value is possible with dilution of the sample.

3

Detection limit for monoclonal immunoglobulin is 1.0 g/L.

4

Detection limit for monoclonal immunoglobulin is between 0.12–0.25 g/L.

5

Name regarding the time of measurements; otherwise Beckman Coulter.