Skip to main content
. Author manuscript; available in PMC: 2014 Dec 1.
Published in final edited form as: Cancer Lett. 2013 Aug 11;341(2):132–138. doi: 10.1016/j.canlet.2013.08.008

Table 1.

A summary of the most commonly used imaging modalities.

Imaging Modality Resolution Sensitivity
[Moles/l]
Imaging Agents Cost Clinical/
Animal Use
PET 1-2 mm
(microPET);
4-5 mm (clinical
PET)
~1011-10
12
FDG, FLT, choline,
acetate,
nitroimidazole,
antibody and
antibody fragments
High Yes/Yes
CT 15-200 m ~10−4 Iodine
Barium
High Yes/bone and
lung imaging
MRI 10-100 m ~10−3-10−5 Gadolinium (+3), iron
oxide particles,
manganese oxide
High Yes/Yes
Ultrasound >40 m a single
bubble
Contrast microbubles Low Yes/Yes
Bioluminescence
Fluorescence
several mm
2-3 mm
~10−15 Fluorescent
molecules and dyes,
targeted
nanoparticles
Low No/Yes