Table 2.

Strains at three mid-diaphyseal gauge sites for applied force of −10N (microstrain, mean ± SD).

Method Antero-lateral gauge site
Antero-medial gauge site
Postero-lateral gauge site
5 Month 12 Month 22 Month 5 Month 12 Month 22 Month 5 Month 12 Month 22 Month
Experimentala (strain gauge) −826 ± 252  −678 ± 319  −864 ± 522 1453 ± 280 1640 ± 602 1886 ± 784 −2132 ± 526 −2329 ± 126 −2947 ± 684
Numericalb (FEA) 439 −893 ± 239 −1001 ± 431 −1228 ± 507 1216 ± 255  947 ± 439 1169 ± 525 −1957 ± 628 −2108 ± 658 −2637 ± 431
a

Experimental values were computed from individual regression lines for each specimen, then averaged; n=4–5.

b

Numerical values were computed from average surface strains at gauge locations for each model, then averaged; n=4–5.