Skip to main content
. Author manuscript; available in PMC: 2015 Jan 22.
Published in final edited form as: J Biomech. 2013 Nov 13;47(2):451–457. doi: 10.1016/j.jbiomech.2013.10.052

Table 3.

Peak strains at the mid-diaphysis for applied force of −10N (microstrain, mean ± SD).

Method Peak compression surface
Peak tension surface
5 Month 12 Month 22 Month 5 Month 12 Month 22 Month
Experimentala (strain gauge) −2816 ± 589 −3036 ± 412 −3506 ± 872 2051 ± 399 2980 ± 224 3194 ± 554
Numericalb (FEA) −3133 ± 964 −2833 ± 988 −3656 ± 1575 1754 ± 615 1691 ± 515 1836 ± 650
a

Experimental values extrapolated from strain gauge sites to locations at maximal distance from neutral axis; n=4–5 specimens/group.

b

Numerical values were averaged over 100 elements at sites of peak compression and tension for each model; n=4.