Skip to main content
. Author manuscript; available in PMC: 2015 Jan 22.
Published in final edited form as: J Biomech. 2013 Nov 13;47(2):451–457. doi: 10.1016/j.jbiomech.2013.10.052

Table 5.

Values of force (rounded to nearest 0.5 N) to engender target peak compressive strain of approximately −3000 με at the mid-diaphyseal periosteal surface in tibiae of 5-, 12-, and 22- month female C57Bl/6 mice.

Age
(month)
Force
(N)
Peak
compressive
periosteal
strain (με)
Peak tensile
periosteal
straina (με)
Strain at
postero-lateral
gauge site (με)
Strain at
antero-
medial gauge
site (με)
 5 −10.5 −2970 2170 −2250 1540
12 −10.0 −3040 2980 −2330 1640
22  −9.0 −3080 2810 −2590 1650

Peak compressive and tensile values determined from regression lines of force vs. peak strain.

Gauge-site values determined from regression lines of force vs. gauge-site strain (Fig. 5).

a

Peak tensile values are observed on the anterior spine that extends from the cross-section.