Skip to main content
. 2014 Jan 27;9(1):e81699. doi: 10.1371/journal.pone.0081699

Table 2. Apparent loss of prognostic power of Peak VO2 threshold over time and likelihood of different prognostic thresholds giving positive results.

Number of studies testing a peak VO2 threshold and finding it to be prognostically significant Number of studies testing a peak VO2 threshold and finding it to be not prognostically significant
Publication year
1986–1990 3 (100%) 0 (0%)
1991–1995 4 (80%) 1 (20%)
1996–2000 6 (75%) 2 (25%)
2001–2005 3 (38) 5 (62%)
2006–2010 2 (22%) 7 (78%)
Threshold tested (ml/kg/min)
9–10.9 2 (100%) 0 (0%)
11–12.9 1 (100%) 0 (0%)
13–14.9 11 (44%) 14 (56%)
15–16.9 2 (66%) 1 (34%)
17–18.9 2 (100%) 0 (0%)