Skip to main content
. Author manuscript; available in PMC: 2014 Feb 3.
Published in final edited form as: IEEE Trans Biomed Eng. 2012 Jun 8;59(8):2338–2347. doi: 10.1109/TBME.2012.2203820

Table II.

Optimized parameters of the point contact equivalent circuit model for the ‘on-cell’ neuron-patch electrode interfaces for (A) Cell 1 and (B) Cell 2b.

A.
a j C e R ext R int R s R sp R e
Sub 0.62 6.00 4.25e-5 5.20e-3 1.56e-1 5.00e-3 O
Sup O O 2.40e-6 1.65 5.39e-1 6.18e-2 O
B.
a j C e R ext R int R s R sp R e
Sub 0.89 4.71e-1 1.28e-4 1.20e-1 6.75e-2 1.85e-1 3.31e-2
Sup O O 3.86e-4 1.17 1.28e-1 5.18e-3 O
b

The symbol ‘O’ stands for the point contact equivalent circuit model parameters fixed at values obtained from sub-threshold optimization of the model parameters for the neuron-electrode interfaces. The fractional surface area of the attached membrane is reported as a percentage of the total membrane surface area; all resistances are in gigaohms (GΩ) and the capacitances are in picoFarads (pF) . ‘Sub’ and ‘Sup’ refer to sub- and supra-threshold stimulations respectively.