Published in final edited form as: IEEE Trans Biomed Eng. 2012 Jun 8;59(8):2338–2347. doi: 10.1109/TBME.2012.2203820

Table IV.

Optimized parameters of the point contact equivalent circuit model of the neuron-microelectrode interface for Cell 1b.

a j C md C ed C e C sh R ext R int R md R s R ed R e
Sub 12.6 3.39 2.32e-1 5.00e+3 5.80e-3 4.91e-3 3.14e-2 2.82e-2 1.60e-4 4.44e-3 2.71e-4
Sup O 3.37 2.22e-1 O O 2.53e-5 2.95e-2 3.08e-2 1.38e-4 3.57e-3 O
b

The symbol ‘O’ stands for the point contact equivalent circuit model parameters fixed at values obtained from sub-threshold optimization of the model parameters for the neuron-electrode interfaces. The fractional surface area of the attached membrane is reported as a percentage of the total membrane surface area; all resistances are in gigaohms (GΩ) and the capacitances are in picoFarads (pF). ‘Sub’ and ‘Sup’ refer to sub- and supra-threshold stimulations respectively.