Skip to main content
. 2014 Jan;58(1):424–431. doi: 10.1128/AAC.01558-13

TABLE 2.

Total posaconazole concentrations in serum and plasma samples and concentrations in samples received from pediatric hospitalsa

Population No. of levels measured Concn range (μg/ml) Median quantifiable concn (μg/ml) % of measurements below LLQ (<0.125 μg/ml) % of measurements below 0.5 μg/ml % of measurements below 0.7 μg/ml % of measurements below 1.25 μg/ml
Total 1,548 Undetectable–6.57 0.64 9.60 34.60 58.40 81.10
Pediatric 152 Undetectable–3.99 0.52 12.50 54.60 63.80 80.30
a

Concentrations were measured by HPLC. LLQ, lower limit of quantification.