Skip to main content
. 2014 Jan;58(1):424–431. doi: 10.1128/AAC.01558-13

TABLE 3.

Itraconazole and itraconazole/hydroxyitraconazole concentrations in serum and plasma samples

Assay and drug No. of levels measured Concn range (μg/ml) Median quantifiable concn (μg/ml) % of measurements below LLQa % of measurements below 0.5 μg/ml % of measurements above 17.1 μg/ml Median matched hydroxyitraconazole/itraconazole ratio (range)
UPLC/MS
    Itraconazole 689 Undetectable–7.37 0.84 38 54.60 1.59 (0.2–3.63)
    Hydroxyitraconazole 676 Undetectable–7.31 1.13 25.30
    Itraconazole + hydroxyitraconazole 651 Undetectable–14.01 1.71 26.30 42.40
Bioassay
    Itraconazole/hydroxyitraconazole 3,105 Undetectable–>20 4.75 18 3.00
a

The lower limit of quantification (LLQ) was <0.25 μg/ml for UPLC/MS and <0.5 μg/ml for bioassay.