Table 1.

Mean geometric, mechanical, and related information for common carotid arteries from n = 16 male control mice. All metrics depending on the model parameters (e.g., systolic dimensions, stress, and stiffness) were found by analyzing individual data and then averaging across the group. See Figures 25 for associated results from mechanical testing. A superscript “a” or “b” indicates data from Schildmeyer et al.68 or Hartner et al.,36 respectively.

n 16
Age (weeks) 9.0 ±1.5
Body Mass (g) 22.9 ± 3.5
Systolic Blood Pressure (mmHg) 116±7a,b
Unloaded Dimensions
 Outer Diameter (μm) 394 ±34
 Wall Thickness (μm) 94 ±15
In vitro Axial Length (mm) 4.66 ± 0.83
Systolic Dimensions
 Outer Diameter (μm) 647 ±38
 Wall Thickness (μm) 26 ±3
In vivo Axial Stretch 1.72 ±0.07
Systolic Cauchy Stresses (kPa)
 Circumferential 177.4 ±20.4
 Axial 199.8 ±29.5
Systolic Stiffness (MPa)
 Circumferential 1.46 ±0.38
 Axial 3.03 ± 1.04