Table 1.
Target Temperature | Heating Time to Tagret Temp. | Temp. Deviation after reaching Target Temp. | Temp. Difference Sensor - IR Camera | Final Relative Shrinkage; Model Estimates |
---|---|---|---|---|
(°C) | MEAN ± SD (s) | ± SD (°C) | MEAN (°C) | MEAN (%) [95 %CI] |
60 | 55.6 ± 5.9 | ± 0.6 | 2.5 | 12.3 [9.6, 15.0] |
65 | 65.4 ± 7.0 | ± 0.5 | 4.1 | 13.8 [11.6, 16.0] |
75 | 70.7 ± 7.2 | ± 0.6 | 7.8 | 16.6 [14.9, 18.2] |
85 | 82.4 ± 10.5 | ± 0.8 | 10.5 | 19.2 [17.1, 21.2] |
95 | 94.3 ± 35.4 | ± 0.9 | 13.0 | 21.7 [18.7, 24.6] |
Note: 7 samples were measured for each target temperature which gives a total of 35 experiments; the heating time for each experiment was 1000 seconds