Skip to main content
. Author manuscript; available in PMC: 2014 Jul 15.
Published in final edited form as: Int J Radiat Oncol Biol Phys. 2013 May 18;86(4):665–670. doi: 10.1016/j.ijrobp.2013.03.035

Table 1. Dose Constraints to Organs at Risk.

Target Current Dose-Volume Constraints for Standard Fractionated Regimens at our Institution (2-Gy Fractions to 60-74 Gy) Dose-Volume Constraints in Current Study [BED dose assuming α/β=3 with 15-fraction regimen)
Total Lung V20 <40%
Mean Lung Dose <20 Gy
V17<40%
Mean Lung Dose <17.5 Gy(RBE) [17.1 Gy(RBE)]
Liver 40% <50 Gy 40% <40 Gy(RBE) [38.9 Gy(RBE)]
Kidneys (both) 1/3 <20 Gy 1/3 <18 Gy(RBE) [17.1 Gy(RBE)]
Esophagus 20% <70 Gy
50% <50 Gy
20% <55 Gy(RBE) [52.65 Gy(RBE)]
50% <40 Gy(RBE) [38.9 Gy(RBE)]
Heart 50% <30 Gy
40% <40 Gy
50% <25 Gy(RBE) [24.6 Gy(RBE)]
40%<32 Gy(RBE) [31.9 Gy(RBE)]
Spinal Cord Maximum dose 45 Gy Maximum dose 36 Gy(RBE) [35.4 Gy(RBE)]
Brachial Plexus Maximum dose <60 Gy Dose to <1 cm3 must not exceed 50 Gy(RBE) [45.6 Gy(RBE)]