Table 2.
Fracture type | Operative fixation technique | Operative indications | Possible complications |
---|---|---|---|
Metacarpal shaft | Long oblique fractures: lag screws Oblique or transverse fractures: plates or IM pinning Multiple fractures: plates |
Displaced, irreducible fractures Shortening >6 mm Residual angulation >30–40° in small/ring fingers or >10° in middle or index finger Malrotation Segmental fractures |
Pseudoclawing Extension lag Malrotation Stiffness |
Metacarpal neck | Intramedullary/Bouquet pinning Transverse pinning Crossed pins |
Malrotation Unstable fractures |
Loss of knuckle prominence Extension lag Stiffness |
Metacarpal head | K-wire fixation Lag screw |
Intra-articular fractures with step-off >1 mm, or >25 % articular surface involvement | Joint arthrosis Stiffness |