Table 3.

Hearing preservation participant demographic information including age at testing, years of electric experience, implant, processor, aided speech intelligibility index (SII) at 60 dB SPL in both the implanted and non-implanted ears, and CNC monosyllabic word recognition (% correct) in the following conditions: HA in implanted ear (ipsi HA), HA in non-implanted ear (contra HA), CI only, CI + ipsi HA, CI + contra HA, and CI + bilateral HAs.

Subject Age Years exp CI Implant Processor Aided SII non-CI ear Aided SII CI ear CNC ipsi HA CNC contra HA CNC CI only CNC CI + ipsi HA CNC CI + contra HA CNC CI + bilateral HA
1 71 1.1 Hybrid L24 Hybrid Freedom 31 24 24 26 68 82 74 78
2 70 4.7 CI24RCA Freedom 18 6 0 10 94 90 98 94
3 69 1.0 Hybrid S8 Hybrid Freedom 57 44 16 50 42 74 78 82
4 52 0.7 CI512 CP810 46 9 6 54 98 96 98 98
5 49 4.5 CI24RE(CA) Freedom 30 10 4 4 90 90 96 98
6 79 1.7 CI24RE(CA) Freedom 12 16 0 26 80 92 96 94
7 61 2.1 Hybrid L24 Hybrid Freedom 32 34 21 48 76 94 90 88
8 61 1.0 CI512 CP810 19 6 10 30 84 82 80 84
9 45 1.4 Sonata (H) Opus2 30 6 2 44 82 84 82 84
10 53 4.0 Hybrid S8 Hybrid Freedom 38 34 28 36 44 60 62 80
11 58 6.4 CI24RCA CP810 31 16 18 24 82 86 84 86
12 52 2.0 Hybrid S8 Hybrid Freedom 32 12 12 48 62 58 86 86
13 34 4.1 CI24RCA Esprit 3G 35 9 2 28 80 84 88 90
14 52 1.4 Hybrid L24 Hybrid Freedom 44 36 26 52 76 90 88 88
15 77 0.6 Sonata (H) Opus2 22 12 0 14 48 56 46 56
16 83 0.9 CI422 CP810 29 15 0 12 26 42 40 46
MEAN 58.9 2.4 N/A N/A 31.6 18.1 10.6 31.6 70.8 78.8 80.4 83.3