Skip to main content
. 2014 Feb 25;5:140. doi: 10.3389/fpsyg.2014.00140

Table 3.

Estimated parameters in fitting a decay function for the mean tap asynchronies.

Exposure type Lag (ms) Pre-test
Post-test
P0 (Starting point) P1 (Rate of change) P2(End point) P0(Starting point) P1(Rate of change) P2(End point)
Mixed-exposure 50 -73.0 (5.2) 0.010 (0.344) -187.7 (3.7x103) -86.1 (4.4) 0.334 (0.113) -113.0 (2.1)
150 -69.8 (4.8) 0.013 (0.242) -185.2 (1.9x103) -87.9 (6.1) 0.289 (0.082) -139.0 (3.9)
Pure-exposure 50 -85.8 (8.2) 0.011 (0.508) -200.2 (5.1x103) -80.2 (34.8) 0.816 (1.612) -98.1 (2.9)
150 -78.6 (11.3) 0.016 (0.421) -207.0 (3.0x103) -79.5 (48.6) 0.890 (0.713) -137.4 (3.3)

Standard errors are shown in parenthesis.

Note: the decay function is, f(x)=P2 + (P0 - P2 ) × exp (-P1 × x)