Skip to main content
. 2014 Jan 30;15(2):293–304. doi: 10.1007/s10162-013-0437-5

TABLE 2.

Summary of generalized linear modeling of focused PA threshold and medial–lateral electrode distance from the modiolar wall

Research ID Mean distance (mm) Mean threshold (dB) # of MOA Thrsh # of Adptv Thrsh Threshold at mean distance (dB) r 2 RMSE (dB)
S36 0.97 54.60 5 0 52.96 0.62 5.93
S38 1.12 50.47 6 0 48.00 0.57 4.95
S40 0.96 46.15 9 3 45.81 0.32 3.03
S41 0.95 43.78 5 0 43.37 0.18 5.79
S54 1.19 57.02 5 2 54.92 0.07 6.25
S55 0.82 46.24 0 6 46.19 0.01 2.59
S66 0.71 45.12 4 0 46.86 0.46 4.15
S80 0.72 47.53 0 3 51.61 0.65 3.71
S89 0.63 53.21 0 3 57.30 0.41 4.64
S101 0.82 53.11 0 3 53.80 0.34 3.75
Mean 0.89 49.72 3.4 2.0 50.08 4.48

The table shows subject and mean values for mean distance from the modiolar wall (in mm), mean threshold (in dB re 1 μA), number of method of adjustment (MOA) thresholds per electrode, number of adaptive thresholds per electrode, threshold at the overall mean distance (at 0.89 mm in dB re 1 μA), r 2, and root mean square error of the linear fit (RMSE dB)