Table 1.
Description | CC1-3D | CC2-3D | CC3-3D | CC4-3D | CC5-3D |
---|---|---|---|---|---|
Offset distance (mm) | 0.00 | 0.41 | 0.83 | 1.24 | 1.65 |
Air inlet hole diameter (mm) | 3.16 | 2.78 | 3.17 | 2.78 | 3.08 |
Air flow rate (L min−1) | 50 | 40 | 50 | 43 | 50 |
Emitted (%)* | 66.2 (1.8) | 68.4 (3.6) | 67.0 (10.0) | 64.9 (17.3) | 6.3 (63.9)** |
Capsule retention (%)* | 13.7 (10.5) | 13.5 (17.4) | 10.1 (6.7) | 14.4 (50.3) | 90.4 (5.4)** |
Capsule chamber retention (%) | 6.1 (17.3) | 5.4 (30.3) | 12.0 (40.4) | 9.8 (81.9) | 2.1 (55.1) |
Mouthpiece retention (%)* | 14.1 (4.4) | 12.7 (8.0) | 10.9 (21.7) | 10.9 (21.2) | 1.1 (37.7)** |
FPF<5µm/ED (%)* | 93.8 (0.7) | 93.6(1.1) | 94.3 (3.0) | 89.7 (1.0) | 75.3 (16.4)** |
FPF<1µm/ED (%)* | 30.9 (1.9) | 32.7 (4.1) | 31.7 (3.4) | 28.6 (7.3) | 20.8 (30.3)** |
MMAD (µm)* | 1.47(1.22) | 1.46 (2.54) | 1.44 (0.68) | 1.55 (3.76) | 1.83 (15.39)** |
P<0.05 significant effect of air inlet staggering on % emitted, capsule & mouthpiece retentions, FPF<5µm/ED, FPF<1µm/ED and MMAD (one-way ANOVA).
P<0.05 significant effect of % emitted, capsule & mouthpiece retentions, FPF<5µm/ED, FPF<1µm/ED and MMAD compared to CC1-3D (post-hoc Tukey).
Batch-1 EEG formulation combination particles generated by Büchi Nano Spray Dryer (B-90).