Skip to main content
. Author manuscript; available in PMC: 2015 Apr 1.
Published in final edited form as: Eur Radiol. 2013 Dec 11;24(4):850–856. doi: 10.1007/s00330-013-3081-x

Table 3.

Descriptive statistics of flow and wall parameters for patients with normal femoral arteries and patients with wall thickening or femoral artery plaque at the location of 2D CINE PC imaging.

peak mean
systolic
velocity
[m/s]
flow
[ml/cycle]
WSS
[N/m2]
peak
systolic
WSS
[N/m2]
OSI
[%]
no wall abnormalities
at site of PC-MRI
(n=15)
0.34 ± 0.10 2.8 ± 1.1 0.83 ± 0.39 1.29 ± 0.55 23 ± 10
wall thickening (n=9) 0.31 ± 0.22 1.6 ± 1.6 0.73 ± 0.40 1.39 ± 0.77 17 ± 6
plaque (n=20) 0.46 ± 0.21 2.6 ± 1.2 0.67 ± 0.17 1.41 ± 0.55 19 ± 9
loose matrix (n=5) 0.55 ± 0.21 3.1 ± 1.3 0.69 ± 0.11 1.53 ± 0.48 20 ± 7
lipid rich (n=2) 0.50 ± 0.29 2.7 ± 0.6 0.68 ± 0.22 1.58 ± 0.82 15 ± 4
calcified (n=13) 0.42 ± 0.20 2.3 ± 1.3 0.67 ± 0.19 1.34 ± 0.57 19 ± 10