Figure 3.

Figure 3.

Noise signal in the excitation current on the order of ΔI/IDC∼5×10-3 in TARN2, caused by a thyristor power supply containing both incoming (main) and reflected waves measured in one magnet. The main noise has a period of 195 µs (the time difference between two peaks of the first signal) and the reflected one of 200 µs with a time delay of 267 µs.