Skip to main content
. 2013 Jul 9;36(2):157–175. doi: 10.1007/s10827-013-0463-7

Table 5.

Comparison of simulation parameter constraints and experimental data

Constraint ON RGCs Model Constraints Experimental data
C0 Spikes overshoot 0 mV
C1 ON resting potential [−62, −70] mV −65.5± 1.3 mV
C2 ON Spontaneous Frequency 0 Hz 0 Hz
C3 ON Spike rate during 500 ms stimulus of −0.2 nA 0 Hz 0 Hz
C4 ON Burst rate at the termination of 500 ms stimulus of −0.2 nA 0 Hz 0 Hz
OFF RGCs Model Constraints Experimental data
C0 Spikes overshoot 0 mV
C1 OFF resting potential [−50, −62] mV −54.6 ± 1.0 mV (OFF T) −55.1± 1.1 mV (OFF S)
C2 OFF Spontaneous Frequency [15, 23] Hz (OFF T) 20.3 ± 3.0 Hz (OFF T)
[40, 48] Hz (OFF S) 43.3 ± 3.5 Hz (OFF S)
C3 OFF Spike rate during 500 ms stimulus of −0.2 nA 0 Hz 0 Hz
C4 OFF Burst rate at the termination of 500 ms stimulus of −0.2 nA Rebound excitation ≥ 2 × spontaneous frequency Rebound excitation 60 Hz