Table 7.

Mean exposure and effective dose to the operator per case from endoscopic retrograde cholangiopancreatography

Author (Publication Year) a Physician Type b No of Cases c KAP d, l (Gy cm2) Fluoroscopy Time d (min) Protective Measures e Mean Badge Dose per Case (μSv) d, f Effective Dose k (μSv) Note

Apron (mm) Thyroid Shield (mm) Hand g Eye Level h Neck i Trunk j
Over Apron Under Apron
ERCP (Diagnostic)
Chen et al. (1996) Endoscopist 4 - - O O - - - 2.5 (±5) - 0.2 With ceiling-suspended shield
Chen et al. (1996) Endoscopist 4 - - O O - - - 15 (±19) - 1.1 Without ceiling-suspended shield
Cohen et al. (1979) Endoscopist 15 - 10 (±4.4) 0.5 - <30 <30 <30 - - 2.1
ERCP (Therapeutic)
Buls et al. (2002) NS 25 50(24–60) iq 6 (3.6–8.3) iq 0.5 X 640 (200–880)iq 550 (160–660)iq 450 (170–600)iq - - 31.5 Over-couch fluoroscopy
Chen et al. (1996) Endoscopist 6 - - O O - - - 2.8 (±4.4) - 0.2 With ceiling-suspended shield
Chen et al. (1996) Endoscopist 6 - - O O - - - 32 (±45) - 2.2 Without ceiling-suspended shield
Krueger and Hoffman (1992) Endoscopist 10 - 7.5 0.5 - - - 6.2 3.3 0 0.4
ERCP (Diagnostic + Therapeutic)
Olgar et al. (2009) NS 31 - - 0.5 0.5 835 94 75 - 0 4.5
Oonsiri et al. (2007) Radiologist 10 35 (9.6–105) 1.7–23 O O - - 170 (98–318) - - 11.9
Naidu et al. (2005) NS 61 - 4.8 0.25 X - - 457 - 23 49 Over-couch system
Heyd et al. (1996) NS 25 - - - - - - - 6 - 0.4
a–k

See footnotes to Table 1.

l

Kerma-area product.