Figure 5.

Figure 5

Hydraulic conductivity of membrane coculture [a(EC);b(SMC)], and resistances-in-series model predictions [a(EC)] + [b(SMC)] normalized to the mean Lp of paired endothelial monocultures [a(EC)]. Each culture was supplied with 10FB-MEM or 2.5FB-MEM. Statistical significance (p < 0.05) of membrane coculture Lp compared to resistances-in-series Lp was denoted by (■ vs [a(EC)] + [b(SMC)]). All experiments were n = 6.