Table 1.

Method validation of kisspeptin-10 in rat plasma.

Concentration (ng/mL)

0.5 1 5 50 500
Within-run #
1 0.45 1.21 5.58 50.37 628.88
2 0.50 1.36 6.21 54.94 556.13
3 0.51 1.10 5.84 50.65 574.99
4 0.45 1.30 6.08 53.37 566.30
5 0.55 0.89 5.97 51.19 588.15
6 0.49 1.03 5.10 47.20 516.16
Average ± SD 0.49 ± 0.04 1.15 ± 0.18 5.80 ± 0.40 51.29 ± 2.67 571.77 ± 37.17
CV(%) 7.8 15.4 7.0 5.2 6.5
Accuracy 98.3 115.0 116.0 102.6 114.4
Recovery (%) 76.0 83.9 103.3 97.8 81.5
Between-run #
1 0.47 0.99 5.23 50.30 510.24
2 0.65 1.00 4.77 50.25 523.12
3 0.58 0.95 5.04 50.03 512.78
4 0.50 1.00 5.58 50.83 507.02
5 0.46 1.11 5.05 50.18 523.12
6 0.49 1.27 5.16 46.26 512.05
Average ± SD 0.53 ± 0.07 1.05 ± 0.12 5.14 ± 0.27 49.64 ± 1.68 514.72 ± 6.80
CV(%) 14.2 11.3 5.2 3.4 1.3
Accuracy 105.0 105.3 102.8 99.3 102.9