Skip to main content
. 2014 Mar 18;4:4407. doi: 10.1038/srep04407

Table 3. Comparison of NIF with various sandwich ELISA procedures and the commercial kits for the detection of HFA.

Manufacturer/Immunoassay Procedures Antibody binding Sensitivity (ng mL−1) References
New ELISA format (NIF) One-step 0.01 This work
ELISA-covalent binding of antibody Covalent 0.03 This work5 using the covalent immobilization of the antibody as described by Dixit et al.5
Conventional ELISA Passively adsorbed 0.5 This work
RnD systems Passively adsorbed 0.37 http://www.rndsystems.com/pdf/DY1184.pdf
Biovendor Passively adsorbed 0.35 http://www.biovendor.com/product/immunoassays/fetuin-a-ahsg-human-elisa
Alpco Diagnostics Passively adsorbed 5.00 http://www.alpco.com/pdfs/43/43-NSEHU-E01.pdf
Immunology Consultants Laboratory, Inc. Passively adsorbed 6.25 http://www.life-sciences.com.br/pdf/icllab.pdf
Genway Biotech, Inc. Passively adsorbed 6.25 http://www.genwaybio.com/images/gw_tds/elisa_kits/40-374-130036.pdf
Assay Pro Passively adsorbed 6.25 http://www.assaypro.com/datasheet/eg3501_1.pdf