Skip to main content
. 2014 Feb 19;14(2):3428–3444. doi: 10.3390/s140203428

Table 5.

Modidfied-EPSA FDI performance in CASE2.

F/N Ratio 2 3 4 5 6 7 8 9 10

Fault detection number 0 0 45 251 746 992 1,000 1,000 1,000 1,000
Fault isolation number #1 0 0 27 200 675 963 981 992 1,000 1,000
#2 0 0 38 196 672 960 1 992 1,000 1,000
#3 0 0 7 6 23 24 19 7 0 0
#4 0 0 5 5 7 1 1 0 0 0
#5 0 0 3 4 5 2 0 1 0 0
#6 0 0 5 9 7 2 0 1 0 0
#7 0 0 2 11 28 25 18 7 0 0