Table 1.

Calculated exposure time (sec) of nonthermal light technologies at selected distances from the light source.

Dose per treatment (J/cm2)
0.18 0.36 0.72 1.44 2.832 6 17.7 27 36 54 106.2
Distance from light source (cm) 3 NUV-VIS 6 11 22 45 88 186 548 836 1115
12 28 55 110 221 435
23 149 298 595 1190 2341
6.5 UV 30 60 120 240 472
17 36 72 144 288 566
28.5 45 90 180 360 708
2.5 HILP NT NT NT NT 0.8 NT 5 NT NT NT 30
8 0.1 0.2 0.4 0.8 NT NT NT NT NT 30 NT
11.5 NT 0.3 0.6 NT NT 5 NT NT 30 NT NT
14 0.2 0.4 0.8 NT NT NT NT 30 NT NT NT

NUV-Vis: near UV-vis light; UV: ultraviolet light; HILP: high-intensity light pulses.

(∗) Samples that are not analyzed due to high temperature, NT: not tested samples.

Distance from light source (cm).

HILP was applied in pulses 360 μs duration at a frequency of 3 Hz.