Skip to main content
. 2014 Mar 17;9:1423–1432. doi: 10.2147/IJN.S57353

Table 1.

Biomechanical results comparing n-HA/PA66/GF plate to titanium plate for fixation

Constructs Stiffness
Failure strength
Bending (N/mm) Torsion (Nm/°) Bending (Nm) Torsion (Nm)
HPGP 244.1±49.6 0.16±0.04 11.2±2.4 6.0±1.6
TP 370.6±33.9 0.37±0.05 38.7±2.3 12.1±1.2
P-value 0.022 0.006 <0.001 0.007

Note: The data was analyzed by Student’s t-test.