Fig. 2.
Ba2+ permeability of two types of inward currents in ICC. A. Representative current traces recorded with 10 mM Ca2+ or 10 mM Ba2+, respectively. Steps were applied to −40,−20, 0, and 20 mV from a holding of −80 mV in 10 mM Ca2+ (black lines) or 10 mM Ba2+ (red lines). B. current-voltage relationships for peak current (means ± SE) in 2 mM Ca2+ (△), 10 mM Ca2+ (○), and 10 mM Ba2+ (●). C: currents were obtained by ramp depolarization from −80 to +80 mV in 2 mM Ca2+, 10 mM Ca2+, and 10 mM Ba2+.