Table 3.

Electrical parameters for initial, intermediate and final measurements

Parameter Test Condition Min. Max.
Zero-g Level (Voff) T = 25°C Vdd/2-10% Vdd/2+10%
Self test Output Voltage Change (Vt) T = 25°C; Vdd=3.3V Full-scale = 2g; X axis -20mV -100mV
T = 25°C; Vdd=3.3V Full-scale = 2g; Y axis 20mV 100mV
T = 25°C; Vdd=3.3V Full-scale = 2g; Z axis 20mV 100mV
Supply Current (Idd) Mean value Power down (PD) pin connected to GND 1.5mA