Table 1.
Average baseline levels of mean arterial pressure (MAP), heart rate (HR), myocardial contractility (dP/dtmax), and spectral powers of hemodynamic variability at low (0.25–0.75 Hz) and high (0.75–3 Hz) frequency ranges, and spontaneous baroreflex sensitivity (Index α).
| Parameter | OVX | OVXE2 |
|---|---|---|
| MAP (mmHg) | 102.1±1.2 | 96.0±1.4* |
| HR (beats/min) | 352.5±2.8 | 358.5±7.2 |
| dP/dtmax (mmHg/sec) | 1456±79 | 1782±59* |
| IBILF/HF | 2.47±0.28 | 1.55±0.37* |
| SBP-LF (mmHg2/Hz) | 0.16±0.01 | 0.11±0.01* |
| Index α (HF, sec/mmHg) | 1.75±0.11 | 1.40±0.18 |
| Index α (LF, sec/mmHg) | 0.65±0.06 | 0.68±0.11 |
Values are means±SEM of 6–7 observations. MAP, mean arterial pressure; HR, heart rate; IBI, interbeat interval; SBP, systolic blood pressure.
P<0.05 vs. OVX values (unpaired Student's t-test).