Skip to main content
. 2013 Dec 5;15(2):261–269. doi: 10.1208/s12249-013-0054-y

Table II.

Calculation of Liquid Cross Sectional Area (a) and Liquid Fill Height (h) Corresponding to a Fixed Ratio of a/h = 45 mm

Vial size Mean weight (g) ±SD (weight) Mean diameter (mm) ±SD (diameter) a (mean area of liquid (mm2)) ±SD (area) h (mean liquid fill height (mm)) ±SD (fill height)
2 4.420 0.014 15.950 0.010 199.833 0.251 4.433 0.006
4 5.584 0.034 15.983 0.042 200.669 1.046 4.451 0.023
6 7.999 0.085 21.937 0.006 377.996 0.199 8.385 0.004
8 8.639 0.084 21.923 0.076 377.537 2.629 8.375 0.058
10 9.283 0.068 23.957 0.061 450.816 2.299 10.000 0.051