TABLE I.

Summary of execution times (T) and speedups (S) for solving the total system using fine mesh (FM), coarse mesh (CM) and decoupled coarse mesh (dCM). In terms of mesh nodes the CM and dCM meshes were 99.1 × and 68.1 × smaller than the FM mesh, respectively. n is the number of compute cores used.

n TFM
[secs]
TCM
[secs]
SCM
[]
TdCM
[secs]
SdCM
[]

1 26501.0 166.7 158.9 210.2 126.1
4 10381.9 51.1 203.2 67.5 153.8
8 5285.5 28.6 184.8 33.5 157.7
16 3195.3 18.5 172.7 21.5 148.6