Skip to main content
. 2014 Mar 26;41(4):042102. doi: 10.1118/1.4868693

Table 7.

Highest sample size required for three- or one-region approach for abdomen–pelvis protocol performed on 320-row scanner, as a function of anticipated effective dose, precision, and desired confidence level. Sample sizes displayed are for confidence level of 95%, with sample sizes for 90% confidence level in parentheses.

Precision Anticipated effective dose (mSv)
(q [%]) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
2 6727(5558) 1682(1390) 748(618) 421(348) 270(223) 187(155) 138(114) 106(87) 84(69) 68(56) 56(46) 47(39) 40(33) 35(29) 30(25)
5 381(210) 96(53) 43(24) 24(14) 16(9) 11(6) 8(5) 6(4) 5(3) 4(3) 4(2) 3(2) 3(2) 2(2) 2(1)
10 58(39) 15(10) 7(5) 4(3) 3(2) 2(2) 2(1) 2(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1)
15 24(17) 6(5) 3(2) 2(2) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1)
20 14(10) 4(3) 2(2) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1)
50 2(2) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1) 1(1)