Table 2.
Hydrodynamic infusion to liver
| Model | Method | DNA mg (µg/g) | VOL (ml/sec) | RATE | References |
|---|---|---|---|---|---|
| Mouse (0.02–0.03 kg) | |||||
| Tail-vein | 0.025 (1)* | 2 ml | >0.2 ml/sec | [60, 61, 64] | |
| Rat (0.2–0.3 kg) | |||||
| IVC catheter | 0.8 (80) | 15 ml | 0.4 ml/sec | [97] | |
| IVC catheter | 0.15 (110) | 3 ml | 0.4 ml/sec | [112] | |
| IVC catheter | 0.8 (100) | 16 ml | ~2 ml/sec | [113] | |
| Rabbit (~3–4 kg) | |||||
| IVC catheter | 60 (2) | 60 ml | ~2 ml/sec | [94] | |
| Dog (~5–20 kg) | |||||
| IVC catheter | 10–30 (90) | 600 ml | ~2 ml/sec | [97, 98] | |
| IVC catheter | 11 (110) | 200 ml | 20 ml/sec | [103] | |
| Pig (~20–30 kg) | |||||
| IVC catheter | 3 (6) | 150 ml | 5 ml/sec | [114] | |
| IVC catheter | 4 (5) | 100 ml | 7.5 ml/sec | [100] | |
| SVC catheter | 20–50 (33–80) | 300 ml | 20 ml/sec | [115] | |
| IVC catheter | 18 (40) | 370 ml | 1.7 ml/sec | [116] | |
| SLL** catheter | 80 (320) | 800 ml | 40 ml/sec | [101] | |
| SLL** catheter | 60 (~300) | 600 ml | 40 ml/sec | [102] | |
| Human (n = 14) | |||||
| Hepatic vein catheter | 1–45* | 50–300 ml | >1–6 ml/sec | [115] |
Amounts of infused DNA are calculated per weight of the targeted tissue, except where denoted by an asterisk, in which case amounts are for the entire animal. Unless data are specifically reported, the values for DNA delivered per kg target organ weight were calculated assuming the liver was 3% the weight of rabbits, dogs and pigs.
Selected liver lobe.