Skip to main content
. Author manuscript; available in PMC: 2015 Apr 1.
Published in final edited form as: Bone. 2014 Jan 24;61:149–157. doi: 10.1016/j.bone.2014.01.008

Table 1.

Baseline trabecular bone microstructure and stiffness measures and their % changes (mean±SD) over baseline after 12 days of treatment.

Baseline % Changes in 12 days over baseline
VEH ALN PTH PTH+ALN
BV/TV 0.31±0.07 5.7±8.7 % 12.5±3.2 % 32.5±15.3 % 45.1±18.5 %
Tb.N* (1/mm) 5.9±0.7 −2.2±5.5 % 1.0±1.4 % −2.6±8.5 % 1.26±5.5 %
Tb.Th* (mm) 0.069±0.008 8.5±6.3 % 9.8±1.5 % 35.4±9.6 % 34.9±14.2 %
Tb.Sp* (mm) 0.15±0.02 2.4±3.9 % −1.9±1.4 % 2.5±7.3 % 6.2±3.9 %
SMI 1.2±0.6 −0.9±6.0 % 6.4±2.6 % 14.6±7.5 % 26.6±9.0 %
Conn.D (1/mm3) 194±46 −8.5±12.2 % −4.1±9.6 % 18.6±14.4 % 16.3±19.9 %
Tb.Stiff (kN/mm) 82±42 9.2±24.6 % 24.0±13.4 % 68.5±32.5 % 102.8±50.8 %

Significant % changes over baseline are given in bold. Baseline measures are from pooled data of all treatment groups. All parameters were not significantly different among treatment groups at baseline.