Summary of the average absolute error and average relative error for increasing cardiac-induced lung motion magnitude bins.

Motion magnitude bin (mm) Left lung average absolute error (mm) Left lung relative error Right lung average absolute error (mm) Right lung relative error
0.3–1 0.30 ± 0. 09 59.8 ± 35.8% 0.45 ± 0.20 75.4 ± 56.9%
1–2 0.33 ± 0.11 24.9 ± 6.2% 0.53 ± 0.28 34.3 ± 11.8%
2–3 0.32 ± 0.10 13.7 ± 1.2% 0.58 ± 0.34 20.0 ± 4.0%
3–4 0.32 ± 0.11 9.6 ± 0.9% 0.61 ± 0.38 14.2 ± 2.0%
4–5 0.34 ± 0.12 7.7 ± 0.6% 0.61 ± 0.37 11.0 ± 1.2%
5–6 0.35 ± 0.12 6.4 ± 0.4% 0.58 ± 0.33 8.8 ± 0.8%
6–7 0.34 ± 0.12 5.3 ± 0.3% 0.57 ± 0.33 7.0 ± 0.5%
7–8 0.35 ± 0.12 4.7 ± 0.2% 0.56 ± 0.32 5.6 ± 0.3%
8–9 0.35 ± 0.12 4.2 ± 0.2% 0.55 ± 0.30 4.9 ± 0.2%
9–10 0.36 ± 0.13 3.8 ± 0.2% 0.56 ± 0.31 4.2 ± 0.2%
> 10 0.38 ± 0.14 3.4 ± 0.1% 0.60 ± 0.36 3.5 ± 0.1%