Table.

Radiography Densitometer Results

Composite Group Aluminum Equivalentsa,b,c
Commercial control, 3M Corp. Z100 2.51 (± 0.09)
3M Z100 + 35 wt% chopped fibers 1.37 (± 0.21)
Commercial control, Kerr Corp. XRV 2.29 (± 0.05)
Kerr Herculite XRV+35 wt% chopped fibers 1.40 (± 0.06)
Exp. paste + 35 wt% chopped fibers 1.85 (± 0.06)
a

Aluminum equivalents expressed as millimeters of 99.99% pure aluminum thickness per millimeter of composite thickness.

b

ADA Seal of Acceptance Guidelines and ADA Composite Standard #27 for Aluminum Equivalents are 1.5 and 2.0, respectively.

c

Values are means ± 1 standard deviation of 5 specimens (N = 5).