Skip to main content
. 2014 Jan 30;306(8):G711–G727. doi: 10.1152/ajpgi.00449.2013

Table A2.

Parameter values that differ across model variations

Parameter Value Reference
Cl parameters
    [Cl]i
        H 78 mM C
        L 25.85 mM 76
    ECl
        H −20.2 mV C
        L −49.7 mV C
Ion channel maximal conductances
    gAno1
        H(NSV,NSCa) 20 nS
        H(NaV,CaV), L(NaV) 15 nS
        L(NSCa) 10 nS
    gCaT
        H(NaV,NSV,CaV), L(NaV) 3 nS 10
        H(NSCa), L(NSCa) 4 nS
    gKb
        H(NSV,NSCa,CaV) 9 nS
        H(NaV), L(NaV,NSCa) 5 nS
    gNab
        H(NSV,NSCa,CaV) 2 nS
        H(NaV), L(NaV,NSCa) 1 nS
    gNaV
        H(NaV) 6 nS
        L(NaV) 10 nS
    gNSV
        H(NSV) 30 nS
    gNSCa
        H(NSCa), L(NSCa) 30 nS
    gCaV
        H(CaV) 6.2 nS
    gKt
        L(NaV) 6 nS
    gKERG
        L(NaV) 3 nS
Ca2+ pump maximal fluxes
    VPMCA
        H(NaV,NSV), L(NaV) 50 μM/s
        H(NSCa) 100 μM/s
        H(CaV) 1500 μM/s
        L(NSCa) 110 μM/s
    VNCX
        L(NSCa) 225 μM/s

C denotes that the parameter value was calculated using other parameters; see text for other definitions. References are given where available; other parameter values were chosen to reproduce correct slow wave activity. Model variations in which each parameter value is used are denoted by H for High-Cl and L for Low-Cl.