Table 2. Uncertainty associated with ACMs for increasing number of streamlines.

Number of streamlines 10 50 150 300 500 700
Average CV 0.049 0.023 0.014 0.012 0.011 0.012
Average SNR 20.32 44.21 69.44 85.84 87.42 85.54

Legend: Shows the average voxel-wise coefficient of variation (CV) and the average signal to noise ratio (SNR) for repeated ACM estimation to investigate the effect of the number of streamlines. The average CV/SNR values are based on a CV/SNR volume of five healthy subjects where each of the volumes comes from a five times repeated estimation of the same ACM.