Table 1.

Summary of electrical and biological measurement results.

Measurement Value Units
Technology 0.18 (2P/6M) μm
VddA/Vdd/VddD 2.0/ 2.1/ 1.8 V
Readout Columns 16 --
Area (with pads) 2.7 × 2.7 mm × mm
Power Consumption 50.4 mW
Gain 84.9 dBΩ
Sampling Frequency 10 MHz
Oversampling Ratio 500 --
# Sensors 256 --
Readout Time 4 s
Nominal Sensor Resistance 1.84 kΩ
MR Ratio 9.2 %
Input Referred Noise 49 nT/√Hz
DAC DNL −0.32 to 0.31 LSBs
DAC INL −0.23 to 0.18 LSBs
SFDR >80.2 dB
Multitone SFDR 73.0 dB
Adjacent Channel Crosstalk 83.0 dBc
Limit of Detection (SLPI) 10 fM
Linear Dynamic Range (SLPI) 3.5 Decades